Category Archives: Non-Conductive

Q: We are looking to find an electrically   non-conductive bolt that would also work at temperatures up to 500 F max. They will be used for an electrically live part isolation kit. Anything that will fit the bill? A: Without any understanding of your strength requirements, and focusing solely on the … Continue reading

Posted in Application, Engineered Polymer Fasteners, FAQs, High Temperature Resistance, Material, Non-Conductive | Tagged , , , , , , , , , , , , | Leave a comment

Q: We are looking for screws to hold down electronic circuit boards. Unfortunately the mounting provisions need to be electrically isolated from the mounts. In addition,  we need strength, non-conductivity, and impact resistance, even at cold temperatures (-40C). A:  A great material to consider would be PEEK screws or PEEK with Glass Fiber reinforcement.  These … Continue reading

Posted in Application, Engineered Polymer Fasteners, FAQs, High Strength, Non-Conductive | Tagged , , , , , , , , , | Leave a comment

Q: I’m involved in is currently looking at your non-conductive fasteners to isolate an SMA Connector. But have several questions for finding the right solution regarding torque, preload heating and cooling, and locking features. A: Thanks for all the questions and interest. I will answer all your questions: How is torque … Continue reading

Posted in Application, Engineered Polymer Fasteners, FAQs, Material, Non-Conductive, Technical Questions | Tagged , , , , , | Leave a comment

Q: I need a non-conductive screw. Can I use Carbon fiber reinforced PEEK? A: NO – The addition of carbon fibers into the polymer will significantly increase the conductivity of the material.

Posted in Application, Engineered Polymer Fasteners, FAQs, Non-Conductive, Technical Questions | Tagged , , | Leave a comment

Q: We require materials with low outgassing (conforming to ASTM-E595) for use in a satellite and I have yet to find a polymer screw that could meet these requirements. Any ideas? A: I checked PEEK in NASA’s material out-gassing database. It looks like it will most likely meet the 1% … Continue reading

Posted in Application, Engineered Polymer Fasteners, FAQs, Material, Non-Conductive, Technical Questions | Tagged , , , | Leave a comment

Q: I’m currently cruising the internet looking for the best way to support a ceiling via suspension from structural steel. We’re building a freezer, and I don’t want thermal bridging from the inside of the freezer up to the structural steel, so a metal rod is pretty much out of … Continue reading

Posted in Application, Engineered Polymer Fasteners, FAQs, High Strength, Material, Non-Conductive, Technical Questions | Tagged , , , , , , , , , , , , , , , , | Leave a comment

Q: We are attaching steel to aluminum in a drainage pond application, and need to prevent electrolysis. The aluminum materials are degrading prematurely. Is there a non-conductive bolt that would work for this situation? A: Your best bet is if you can use a polymer bolt like PEEK. PEEK bolts … Continue reading

Posted in Application, Engineered Polymer Fasteners, FAQs, Material, Non-Conductive, Technical Questions | Tagged , , , , , , , , | Leave a comment

Q: I’m looking for a polymer insert locknut for a marine environment.  Can you make any suggestions? A:  In your marine lock nut application, the polymer you should consider for the locking mechanism would be PVDF (Kynar). PVDF polymer in combination with the lock nut would perform very well in … Continue reading

Posted in Application, Engineered Polymer Fasteners, FAQs, Material, Non-Conductive, Technical Questions | Tagged , , , , , | Leave a comment

Q: We are looking for high shear strength non-conductive flat head screws being used for electrical insulation. The screws need to have a high shear strength quality as other plastics screws we have tried have broken. Do you have a material you can recommend? A: With regards to a polymer … Continue reading

Posted in Application, Engineered Polymer Fasteners, FAQs, High Strength, Material, Non-Conductive, Technical Questions | Tagged , , , , , , , , , , , , , , , , | Leave a comment

Q: We are looking for a non-conductive screw with lower dielectric constant / dissipation factor to replace a steel screw (Tensile Strength 70kpsi) in one of our products. So were trying to get to similar strength / properties to the steel screw to meet our torque requirements. Will a ceramic … Continue reading

Posted in Advanced Ceramic Fasteners, Application, Engineered Polymer Fasteners, FAQs, Non-Conductive, Technical Questions | Tagged , , , , , , , , | Leave a comment

Q: Looking to change to a non-conductive material for use in a high impact application. Would Alumina or Zirconia ceramic fasteners be a good fit? A: We could certainly quote you some ceramic hardware, however ceramics may not be the best non-conductive choice for a high impact environment.  Ceramic fasteners … Continue reading

Posted in Application, FAQs, High Strength, Non-Conductive, Technical Questions | Tagged , , , , , , , | Leave a comment

Q: I have a need for a fastener for cyrogenic Helium (3.5K) application. Ideally, the fastener would be non conductive (electrically). Are any of the non conductive options you have listed good for cryo use? A: You might want to consider PTFE of PEEK fasteners. These are polymers that will … Continue reading

Posted in Application, Engineered Polymer Fasteners, FAQs, Material, Non-Conductive, Technical Questions | Tagged , , , , , , , , | Leave a comment

Q: I need a bolt that can handle high temperatures and be an electric insulator? What can I use? A: That depends on what you mean by high temperature and what other issues you have like the strength requirements. If you are talking about temperatures under 500F, then you may … Continue reading

Posted in Advanced Ceramic Fasteners, Application, Engineered Polymer Fasteners, FAQs, Non-Conductive, Technical Questions | Tagged , , , , , , , , , , | Leave a comment

Q: I’m looking for a socket head cap screw that is 5/8″-11 x 5.5 inches in length. Need the material to be non-conductive and was thinking Ceramic Zirconia? Would that work? A: Ceramics like Zirconia screws are in fact an excellent insulator from electrical current. However zirconia ceramic fasteners are … Continue reading

Posted in Advanced Ceramic Fasteners, Engineered Polymer Fasteners, FAQs, Non-Conductive, Technical Questions | Tagged , , , , , , , , , , , , , , , , | Leave a comment

Q: I have an application where I need a non-metal fastener because of insulation and magnetic issues. The problem is that it also needs to be able to retain strength at about 520°F. Should I use a ceramic? A: Ceramic fasteners are definitely not necessary at these temperatures, although they … Continue reading

Posted in Application, Engineered Polymer Fasteners, FAQs, High Temperature Resistance, Material, Non-Conductive, Technical Questions | Tagged , , , , , , , , , , | Leave a comment

Q: I am looking for some high tensile strength studs with good electricity resistance. I think zirconia of aluminia material will be suitable but I am open for suggestions. The studs would be about 5 inches long. A: Probably ceramics fasteners are not the best choice for this situation. It … Continue reading

Posted in Advanced Ceramic Fasteners, Application, Engineered Polymer Fasteners, FAQs, High Strength, Non-Conductive, Technical Questions | Tagged , , , , , | Leave a comment

Q: I have an application where I need pan head, insulating, high vacuum compatible, screw. It will also need to be usable at a service temperature up to 150C. Do I need a ceramic? A: Though ceramics are excellent insulators, they are usually only used for high temperature applications, where … Continue reading

Posted in Advanced Ceramic Fasteners, Application, Engineered Polymer Fasteners, FAQs, Non-Conductive, Technical Questions | Tagged , , , , | Leave a comment

threaded-flangeQ: When do you recommend to use a threaded flange? I need a flange that can be changed easily & frequently. A:   After speaking with the customer, I found out that he has a pilot plant where he will be frequently changing parts. In this case a threaded flange is … Continue reading

Posted in Corrosion Resistance, FAQs, High Strength, High Temperature Resistance, Lightweight, Non-Conductive, Specialty Metal Fasteners, Technical Questions, Ultra Purity, Uncategorized | Tagged , , , , , , | Leave a comment

Q: Need to replace a standard steel washer with a non-conductive material. A:   After speaking with this customer, I learned that he needed to replace a standard steel washer with a non-conductive material for a critical bolted joint. These washers needed to withstand 70°C temperatures while maintaining preload. He … Continue reading

Posted in Corrosion Resistance, Engineered Polymer Fasteners, FAQs, Non-Conductive, Technical Questions | Tagged , , , , , , , , , , | Leave a comment

Q: Can you provide alternative for a nylon pan head screw? A:   Here the customer needed an alternative to nylon. Resistance to electrical fields was a primary concern. In addition, he also needed a material that had a better dissipation factor than nylon. In this situation we would recommend PEEK. It … Continue reading

Posted in Engineered Polymer Fasteners, FAQs, High Strength, Non-Conductive, Technical Questions | Tagged , , , , , , , | Leave a comment

Q: Is Alloy 330 Magnetic? A:   Though alloy 330 does contains iron and chromium, it also contains nickel. The nickel component is what helps to strengthen the protective qualities of the chromium however, the presence of nickel also makes this metal non-magnetic. The reason is that the presence of … Continue reading

Posted in FAQs, Non-Conductive, Specialty Metal Fasteners, Technical Questions | Tagged , , , , , | Leave a comment