Q: My customer is having an issue with his stainless steel fastener bending. They are being used in a high-heat application running at approximately 1600F. Is this normal? Any ideas? A: This is definitely expected at these temperatures. If temperature and strength are you main focus, I would suggest either … Continue reading

Posted in Application, FAQs, High Strength, High Temperature Resistance, Specialty Metal Fasteners, Technical Questions | Tagged , , , , , | Leave a comment

Q: I have a high temperature application which is exposed to sulfur and chloride gasses. We’re operating at between 1200° and 1400°F. Any suggestions on a bolt material to consider? A: To deal with both sulfuric/chloride atmospheres as well as high temperatures, you may want to consider Incoloy 800HT bolts … Continue reading