Sie sind sich nicht sicher, welches Material für Ihre Anwendung am besten geeignet ist?
Kontaktieren Sie einen Experten
Suche nach Material
Suche nach Anwendung
Tag Archives: AL6xn chloride resistance
Posted on May 25, 2018 by dean
Q: I need some bolting to attach some surface steam piping for a power industry project. They’re using duplex bolts now but its showing some slight corrosion. Chlorides are involved and maybe some other contaminants. Ideas? A: Surface steam condensers and other power industry elements that are exposed to salts … Continue reading →
Posted in Application, Corrosion Resistance, FAQs, Specialty Metal Fasteners, Technical Questions | Tagged AL-6XN bolts for chloride resistance, AL-6XN bolts for surface steam condensers, AL-6XN fasteners for chloride resistance, AL-6XN for surface steam condenser corrosion, AL-6XN screws for chloride resistance, AL6XN bolts chloride corrosion resistance, AL6XN bolts for chloride resistance, AL6XN bolts for surface steam condensers, AL6XN chloride corrosion resistance, AL6xn chloride resistance, AL6XN fasteners chloride corrosion resistance, AL6XN fastners for chloride resistance, AL6XN for chloride corrosion resistance, AL6XN for surface steam condenser corrosion, AL6XN for surface steam condensers, AL6XN screws chloride corrosion resistance, AL6XN screws for chloride resistance, Alloy K500 bolts for chloride corrosion, Alloy K500 for surface steam condenser corrosion, bolts for surface steam condenser corrosion, bolts for surface steam condensor corrosion, bolts for surface steam condensors, fasteners for surface steam condenser corrosion, Monel for surface steam condensor corrosion, Monel for surface steam condensor corrosion resistance, Monel K500 bolts for chloride corrosion, Monel K500 bolts for surface steam condenser corrosion, Monel K500 fasteners for chloride corrosion, Monel K500 fasteners for surface steam condenser corrosion, Monel K500 for chloride corrosion, Monel K500 for surface steam condenser corrosion, Monel K500 for surface steam condensor corrosion, Monel K500 screws for chloride corrosion, screws for surface steam condenser corrosion | Leave a comment
Posted on February 12, 2018 by dean
Q: We’re setting up a salt brine application for a chemical project. There may be some minimal exposure to some acids. Can I uses titanium bolts? A: Titanium Gr2 and Titanium Gr5 (6Al-4V) fasteners are excellent for almost all salt related environments, but here since you may have exposure to … Continue reading →
Posted in Application, Corrosion Resistance, FAQs, Specialty Metal Fasteners, Technical Questions | Tagged Al-6XN for salt brines, AL6xn chloride resistance, AL6XN for brines, AL6XN for salt brines, Fasteners for Salt brines, Fasteners for salt corrosion resistance, Titanium fasteners in salt brines, Titanium for salt bring | Leave a comment