Sie sind sich nicht sicher, welches Material für Ihre Anwendung am besten geeignet ist?
Kontaktieren Sie einen Experten
Suche nach Material
Suche nach Anwendung
Tag Archives: Super Duplex
Posted on July 5, 2017 by dean
Q: I’m using sodium hypochlorite to control slime and bacteria formation in a power plant water system. It’s in about a 15% solution. I tried using Duplex fasteners thinking they are good with chlorides but I’m having corrosion issues. Any suggestions? A: I think the problem you have is the fact … Continue reading →
Posted on May 20, 2017 by dean
Q: I’m working on a on a geothermal energy drilling project. Carbon steel we’re currently using to bolt drilling components is failing from corrosion. We have corrosive an environment with high levels of sulfur and salt, as well as temperatures to 260C. Any suggestions? A: Super Duplex 2507 is often used … Continue reading →
Posted in Application, Corrosion Resistance, FAQs, Specialty Metal Fasteners, Technical Questions | Tagged Alloy 2507, Crevice Corrosion, Duplex, Duplex 2507, Geothermal drilling, geothermal exploration, geothermal well, Hastelloy, Inconel, pitting corrosion, SCC, Stress Corrosion Cracking, Super Duplex, Super Duplex 2507 | Leave a comment